Loading...
HomeMy WebLinkAbout2021-02-09 PACKET 05.D.Request to use Barn for Lodging 2020 has been a really rough year financially for our event business due to Covid 19 and the barn sat empty for months. Sadly, we are also facing a substantial loss of income in 2021 due to the many wedding dates we gave away for free rescheduling 2020 weddings. In addition, the future for all of us in the event industry is uncertain.. In an attempt to stay in business and to make our barn useful when we can't have events, we are requesting the opportunity to rent out the barn as a vacation rental. We would simply add a shower to the bathroom and improve the existing kitchen. When the barn is used for lodging, we would bring in a couch, chairs, television, tables, lamps, a dining table, two queen beds, night stands, and wall art, etc. Then in preparation for an event, the furniture and furnishings would be removed and put in storage. We have staff to help with the transition as well if needed. During our wedding events, we know that the brides and grooms will love the improved kitchen and bathroom as well! We will run this vacation rental professionally as we have a great track record with the Treehouse and the Corn Crib Cottage rentals since 2015 and 2016. We have experience in marketing vacation rentals and we think there will be great interest in staying in the new Barn Villa. We plan to create a beautiful and unique stay for our guests. This new vacation rental could be a popular addition to Cottage Grove Area tourism bringing income to the area restaurants, stores, gas stations, etc. Additional funds would come to the City thru the Lodging Tax. Also, local jobs would be created for cleaning staff and set up crew. We have spoken to Eric Jenson at Washington County and he looks forward to working with us on this lodging unit. He provided us with the list of requirements (which we are very familiar with) and everything is very doable for us. Eric said he will come and inspect when we are done and that it would be no problem to add the barn to our license. We are very grateful for the City of Cottage Grove because it's been a great place to live, work and have a business. We hope you will consider working with in this attempt evolve, to stay in business and to allow us to make our barn useful and not sit empty in these difficult and uncertain times. r--- ----------------------------------------------------------------------- i CLOSET i EGIRE WqW BEDROOM I I — — — — - — - — ------ — — - — - — — — ®— — — — EVENT SPACE O � Bedroom furnishings e pres'ent for lodging LOADS ARE TRANSFERRED and ren—d for events TO STRUCTURE IN BASEMEN F --- V° I -- I ACCESSIB KITCHEN E E ' CCE TH STaLE BEDROOM U U R LL IN S OW ER WARDROBE EGRESS DOOR `--------------- 3'-0" DOOR NO LATCHES CLOSER COVERED PORCH 3'-D" DOOR NO LATCHES 9 j CLOSER 1 GROUND FLOOR PLAN S1.1 Scale: 1/8" = 1'-0" STRUCTURAL NOTE: MAIN FLOOR LEVEL OF BARN AND LOFT ARE STRUCTURALLY SOUND SHEETINDEX S1.1 BARN LODGING LAYOUT S2.1 LOFT LODGING LAYOUT CODE REVIEW PROJECT TITLE: "HOPE GLEN FARM" CODE ANALYSIS & STRUCTURALUPGRADES ADDRESS 10276 E Point Douglas Rd. S Cottage Grove, MN 55016 CONTACT: MICHAEL BUSHILLA Telephone: 612 751 0300 michael@hopeglenfarm.com Revision Date Signed Commission Number Date XXXXX 02111020 Becklin & Whitney Consulting Engineers, Inc. 139 1st Ave. E, Suite 100 P.O. Box 471 Cambridge, MN 55008 Phone: (763) 689-5631 Fax: (763) 552-5631 Drawn ROBERTO F. CICERO Checked WB I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY REGISTERED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA. William A. Becklin, P.E. DATE: DECEMBER 29, 2020 LIC. NO. 1849 Sheet Name BARN LODGING LAYOUT SCALE: AS INDICATED Sheet S1.1 APPLICABLE BUILDING CODES: 2020 MN State Building Code USES IN BARN BUILDING ARE NOT SEPARATED BY FIRE BARRIERS. PROJECT TITLE: 2020 MN Conservation Code for Existing Buildings THE CONSTRUCTION OF THE BUILDING IS BASED ON THE MOST 2017 NEC RESTRICTIVE USE. (508.3.3) "HOPE GLEN FARM" 2015 MN Plumbing Code 2020 MN Mechanical & Fuel Gas Code FIRE DEPARTMENT ACCESS OPENINGS OF AT LEAST 20 SQ FT MUST CODE ANALYSIS& 2020 MN Accessibility Code BE PROVIDED IN EVERY 50 LINEAL FEET OF WALL OR FRACTION STRUCTURALUPGRADES 2015 MN Commercial Energy Code THEREOF. (903.2.11.1) BASEMENT IS A WALKOUT TO WEST AND HAS 2020 MN State Fire Code WINDOWS AND DOORS FOR ACCESS. Type of Construction = VB Building does not have an automatic sprinkler system THIS CODE REVIEW IS FOR BARN BEING USED FOR LODGING BARN WOULD NOT BE USED FOR ASSEMBLY IF USE IS LODGING. OCCUPANCY = B & R3 F1M Office B 2 192 Mezzanine area NIC (505.2) F1M Loft R3 3 276 Mezzanine area NIC (505.2) Fl Main Rm R3 3 1470 12750 0.12 OK F1 Bride Rm R3 3 256 12750 0.02 OK Fl Kitchen R3 3 100 12750 0.01 OK F1 Bath Rm R3 3 60 12750 0.00 OK F1 Stair R3 3 174 12750 0.01 OK TOTAL FOR FLOOR 2060 12750 0.16 OK BF Mech equip rm B 2 240 12750 0.02 OK BF Storage area R3 3 1640 12750 0.13 OK TOTAL FOR FLOOR 1880 12750 0.15 OK BUILDING TOTAL 2060 6666.24 0.31 OK NUMBER OF STORIES =1 Basement area not included in the total checking allowable area. (506.1.3) Notes: Allowable area is based on Table 506.2 and Section 506. Allowable number of stories is based on Table 504.4 and Section 504 Allowed area increased 41.7% for frontage increase. (506.3) Mezzanine areas are not included in floor or building area (505.2) NOTE: Storage areas were set to the major use occupancy group because these areas are accessory to the major use of the building. (311.1.1) OCCUPANCY OF OFFICE (A) = 1 PERSONS OCCUPANCY OF MAIN ROOM = 4 PERSONS OCCUPANCY OF LOFT = 2 PERSONS OCCUPANCY OF BRIDE ROOM = 2 PERSONS OCCUPANCY OF KITCHEN (A) = 1 PERSONS OCCUPANCY OF BATH (A) = 1 PERSONS OCCUPANCY OF STAIR (A) = 1 PERSONS OCCUPANCY OF 1ST FLOOR = 8 PERSONS TOTAL OCCUPANCY = 8 PERSONS Building and Fire Code issues considered: 1. Construction type: V-B. 2. Occupancy types: B & R3 3. Fire separation between basement and dwelling: One -hour 4. Non -sprinkled. 5. Common path of egress travel: 40 feet. 6. Maximum exit access travel distance: 60 feet. 7. Number of exits provided for main room: Two 8. Every sleeping room shall have not less than one operable emergency escape and rescue opening, Add windows as needed. 9. Exit signs: Provided. 10. Emergency lighting: Provided. 11. Fire alarm system: Provided. 12. Smoke C/O alarms: Required. 13. Fire extinguishers: provide one at each exit door. 14. Door swing: out 15. Panic hardware: Provided. 16. Minimum number of plumbing fixtures: 1 unisex in building PORTABLE FIRE EXTINGUISHERS ARE REQUIRED. (906.1) SEE SECTION 906.1, TABLE 906.1 AND SECTION 906.3. OPEN TO BELOW OFFICE a CLO LOFT AII ET 1 LOFT FLOOR PLAN s1. Scale: 1/8" = 1'-0" V NORTH ADDRESS 10276 E Point Douglas Rd. S Cottage Grove, MN 55016 CONTACT: MICHAEL BUSHILLA Telephone: 612 751 0300 michael@hopeglenfarm.com Revision Date Signed Commission Number Date x02-020 Becklin & Whitney Consulting Engineers, Inc. 139 1st Ave. E, Suite 100 P.O. Box 471 Cambridge, MN 55008 Phone: (763) 689-5631 Fax: (763) 552-5631 Drawn ROBERTO F. CICERO Checked WB I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY REGISTERED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA. William A. Becklin, P.E. DATE: DECEMBER 29, 2020 LIC. NO. 1849 Sheet Name LOFT LODGING LAYOUT CODE REVIEW SCALE: AS INDICATED Sheet S1.2